Electrical Flexible Conduit
Flexible hose electrical products are essential components in various industrial and commercial applications, providing a safe and reliable means of transmitting electrical power and signals. These hoses are designed to accommodate dynamic movement, offering versatility while ensuring protection against environmental factors such as moisture, dust, and chemicals.
Outer layer: PVC (temperature range: -40°C to 120°C).
Inner layer: Non-conductive plastic or vulcanized steel plate, providing additional insulation and wear resistance.
Special design: Spirally wound conductive adhesive to ensure electrical continuity.
Performance advantages
Fatigue resistance: Passed axial torsion test (>1000 cycles without breakage).
Fire rating: Meets UL 360, IEC 61386 standards, suitable for hazardous environments.
Easy installation: Supports quick connector connection to reduce labor costs.
| Material: | High Grade Imported PA6 |
| Color: | Black, Dark Grey, Other colors can be customized |
| Temperature Range: | -40℃ to 125℃ |
| Protection degree: | IP68 |
| Flammability Rating: | UL94V-0 or UL94HB |
| OEM/ODM: | Customization Service Provided |
| Certification: | SGS CE ROHS |
| Features: |
PA flexible conduit flexible and ductile, Medium-duty, Twist-reisistance,high mechanical Strength, Chemical resistance to Oil,alkalies,weak acids and so on. Resistance to abrasion and UV. Free from Halogen and Phosphorus. |
| How to use: |
PA flexible conduit for applications in machinery building,electrical control system,installation industries and so on. Installation Instruction: Insert the wire cable into the conduits, then connect the conduits with matching size connector. |
| Bearing capacity: | PA flexible conduit can bear the weight of foot, no fracture, no deformation, can quickly recover, and itself without any damage,with self-extinguishing and high anti-fatigue strength characteristics, resistance to frequent bending movement. |


| Item No. | Item No. | Conduit Size | Inner dia x outer dia (mm) | Packing unit(meter) |
| black | grey | |||
| GD-PAH-10B | GD-PAH-10G | AD10 | 6.5x10 | 100 |
| GD-PAH-13B | GD-PAH-13G | AD13 | 10x13 | 100 |
| GD-PAH-15.8B | GD-PAH-15.8G | AD15.8 | 12x15.8 | 100 |
| GD-PAH-18.5B | GD-PAH-18.5G | AD18.5 | 14.3x18.5 | 100 |
| GD-PAH-21.2B | GD-PAH-21.2G | AD21.2 | 17x21.2 | 100 |
| GD-PAH-25.5B | GD-PAH-25.5G | AD25.5 | 21x25.5 | 50 |
| GD-PAH-28.5B | GD-PAH-28.5G | AD28.5 | 23x28.5 | 50 |
| GD-PAH-34.5B | GD-PAH-34.5G | AD34.5 | 29x34.5 | 50 |
| GD-PAH-42.5B | GD-PAH-42.5G | AD42.5 | 36x42.5 | 25 |
| GD-PAH-54.5B | GD-PAH-54.5G | AD54.5 | 48x54.5 | 25 |


1. We will prompt reply your e-mail within 24hoers We can answer all your question in English
2. Protection of you sales area, ideas of design and all you private information
3. you are welcomed to contact us, We will try our best you are your request.
4. When you get the goods, test them, and give me a feedback if you have any questions about the problem, contact with us, we will offer the solution for you
5. On time delivery
6.Insist win-win development
7. All the products must must be double checked to ensure the quality before delivery.
Our address
No.173 Xingqiao North Road, Yuhang District, Hangzhou, Zhejiang 31100, China
Phone Number
+86-152 6711 5891
jeson@gordon-elec.com
joyce@gordon-elec.com

FAQ:
1. When using flexible conduits in industrial equipment (such as robotic arms), how can we ensure their anti-vibration and oil pollution performance?
In industrial environments, it is recommended to choose metal flexible conduits (such as galvanized steel strips or stainless steel materials), and their outer plastic coating (PVC/PE) design can resist oil pollution penetration. The spiral structure inside the conduit can absorb vibration energy and reduce fatigue fracture of the cable caused by high-frequency vibration. At the same time, it is necessary to match waterproof sealing connectors (such as IP67/IP68 grades) to prevent oil pollution from entering the conduit.
2. Why do ships and rail transit require specially designed flexible conduits?
The ship and rail transit environment requires conduits to have double protection:
Waterproof: It must reach IP68 level, such as all-plastic LFNC or plastic-coated metal conduits, which can withstand seawater immersion and high-pressure flushing.
Corrosion resistance: Choose stainless steel or nickel-plated conduits to prevent salt spray corrosion.
Impact resistance: The high rigidity of metal conduits can withstand mechanical collisions and ensure line safety.
Hot Tags: electrical flexible conduit, China, suppliers, manufacturers, factory, custom, wholesale, Stainless Steel Cable Tie Tool, porter cable tie downs, nylon coated stainless steel cable ties, Cable Tie With Ball, stainless cable tie, 6 inch zip ties