Contact Us
- No.173 Xingqiao North Road, Yuhang District, Hangzhou, Zhejiang 31100, China
- jeson@gordon-elec.com
- +86-0571-8853 8375

PG29 Nylon Cable Gland
PG29 Thread: Designed with a PG29 metric cable gland thread for cable entry through electrical enclosures, control cabinets, junction boxes, and industrial equipment.
Nylon Construction: Manufactured from PA Nylon, providing electrical insulation, low component weight, and mechanical strength for enclosure cable-entry applications.
Cable Clamping Range: Available for larger cable diameters, with the sealing and clamping structure selected according to the required cable outer diameter.
Sealing & Strain Relief: The gland compresses the sealing element around the cable while the clamping structure secures the cable at the entry point, helping reduce cable movement and limit dust or water ingress.
Industrial Applications: Suitable for power distribution cabinets, industrial machinery, automation equipment, junction boxes, and other electrical enclosures requiring larger-size cable entry.
Hangzhou Gordon Electric Co., Ltd. is one of the most reliable manufacturers and suppliers of pg29 nylon cable gland in China, also supports custom service. Please feel free to wholesale advanced pg29 nylon cable gland made in China here from our factory.
PG29 Nylon Cable Gland Entry & Sealing Performance

PG29 Threaded Mounting
The PG29 Nylon Cable Gland provides secure engagement with compatible enclosure mounting holes, while the locknut fixes the gland firmly to the panel.

Large Cable Clamping Range
The larger gland size is designed for larger cable diameters, with the sealing insert selected according to the actual cable outer diameter.

Compression Sealing Structure
Tightening the gland cap compresses the sealing element around the cable, forming a close interface between the cable and gland body.

Cable Retention & Strain Relief
The clamping structure holds the cable at the entry point and helps reduce cable movement caused by pulling, vibration, or mechanical stress.
Manufacturing & Quality Capability
Installation Method
- Prepare the Mounting Hole: Confirm the enclosure hole matches the required PG29 mounting specification and remove burrs or debris from the hole edge before installation.
- Install the Gland Body: Insert the cable gland through the enclosure panel and secure it from the opposite side with the compatible locknut.
- Insert the Cable: Pass the cable through the gland, ensuring the cable outer diameter falls within the specified clamping range.
- Tighten the Cap: Tighten the gland cap to compress the sealing and clamping components around the cable, then check that the gland and cable remain firmly positioned.
FAQ
How do I select the correct PG29 cable gland for my cable?
Selection should be based primarily on the cable's actual outside diameter. The cable diameter should fall within the gland's specified clamping range to achieve proper sealing and retention.
Can PG29 cable glands be used on thick electrical enclosure panels?
This depends on the available thread length of the selected gland and the enclosure thickness. The gland, locknut, and any sealing washer must provide sufficient thread engagement.
Does the gland need a locknut?
For installation through an unthreaded enclosure panel, a compatible locknut is required to secure the gland body to the panel. Different mounting configurations may require different hardware.
Can the cable gland be installed on a metal enclosure?
Yes. A nylon PG29 gland can be installed on metal electrical enclosures when the mounting hole and panel thickness are compatible with the gland dimensions.
Hot Tags: pg29 nylon cable gland, China, suppliers, manufacturers, factory, custom, wholesale, glands with strain relief, M cable gland, MG Nylon Cable Glands, PG cable gland, pvc gland, watertight cable gland
| PART NO. | APPROX.LENGTH | APPROX.WIDTH | MAX.BUNDLE DIA. | MIN.LOOP TENSILE |
| MM(INCH) | MM(INCH) | MM(INCH) | STRENGTH N(LBS) | |
| GDCT-4.6x150 | 150(5.9) | 4.6(0.181) | 37(1.46) | 600(135) |
| GDCT-4.6x200 | 200(7.87) | 50(1.97) | ||
| GDCT-4.6x250 | 250(9.84) | 63(2.48) | ||
| GDCT-4.6x300 | 300(11.8) | 76(2.99) | ||
| GDCT-4.6x350 | 350(13.78) | 89(3.50) | ||
| GDCT-4.6x400 | 400(15.75) | 102(4.02) | ||
| GDCT-4.6x450 | 450(17.72) | 115(4.53) | ||
| GDCT-4.6x500 | 500(19.69) | 128(5.04) | ||
| GDCT-4.6x550 | 550(21.65) | 141(5.55) | ||
| GDCT-4.6x600 | 600(23.62) | 154(6.06) | ||
| PART NO. | APPROX.LENGTH | APPROX.WIDTH | MAX.BUNDLE DIA. | MIN.LOOP TENSILE |
| MM(INCH) | MM(INCH) | MM(INCH) | STRENGTH N(LBS) | |
| GDCT-7.9x150 | 150(5.9) | 7.9(0.311) | 37(1.46) | 800(180) |
| GDCT-7.9x200 | 200(7.87) | 50(1.97) | ||
| GDCT-7.9x250 | 250(9.84) | 63(2.48) | ||
| GDCT-7.9x300 | 300(11.8) | 76(2.99) | ||
| GDCT-7.9x350 | 350(13.78) | 89(3.50) | ||
| GDCT-7.9x400 | 400(15.75) | 102(4.02) | ||
| GDCT-7.9x450 | 450(17.72) | 115(4.53) | ||
| GDCT-7.9x500 | 500(19.69) | 128(5.04) | ||
| GDCT-7.9x550 | 550(21.65) | 141(5.55) | ||
| GDCT-7.9x600 | 600(23.62) | 154(6.06) | ||
| GDCT-7.9x650 | 650(25.59) | 167(6.57) | ||
| GDCT-7.9x700 | 700(27.56) | 180(7.09) | ||
| GDCT-7.9x750 | 750(29.53) | 191(7.52) | ||
| GDCT-7.9x800 | 800(31.5) | 193(7.59) | ||
| PART NO. | APPROX.LENGTH | APPROX.WIDTH | MAX.BUNDLE DIA. | MIN.LOOP TENSILE |
| MM(INCH) | MM(INCH) | MM(INCH) | STRENGTH N(LBS) | |
| GDCT-12x200 | 200(7.87) | 12(0.472) | 50(1.97) | 1200(270) |
| GDCT-12x250 | 250(9.84) | 63(2.48) | ||
| GDCT-12x300 | 300(11.8) | 76(2.99) | ||
| GDCT-12x350 | 350(13.78) | 89(3.50) | ||
| GDCT-12x400 | 400(15.75) | 102(4.02) | ||
| GDCT-12x450 | 450(17.72) | 115(4.53) | ||
| GDCT-12x500 | 500(19.69) | 128(5.04) | ||
| GDCT-12x550 | 550(21.65) | 141(5.55) | ||
| GDCT-12x600 | 600(23.62) | 154(6.06) | ||
| GDCT-12x650 | 650(25.59) | 167(6.57) | ||
| GDCT-12x700 | 700(27.56) | 180(7.09) |